API RP 1102 Pipeline Railway And Highway Crossing Modules

Links : ±
CALCULATOR MODULE : API RP 1102 Pipeline Crossing Line Pipe Schedule   ±

Calculate API RP 1102 steel pipeline diameter, nominal wall thickness and pressure containment wall thickness.

For API RP 1102, the fabrication tolerance is included in the design factor. The fabrication tolerance is not required provided that the tolerance is within the relevant specification. The pressure containment wall thickness equals the nominal wall thickness minus the corrosion allowance. The pipe diameter can be defined by either the outside diameter or the inside diameter.

Use the Result Table option to display a table of pipe cross section versus wall thickness for the selected diameter.

Reference : API RP 1102 : Steel Pipelines Crossing Railroads and Highways (2012)

Change Module :

CALCULATOR MODULE : API RP 1102 Pipeline Highway Crossing   ±

Calculate API RP 1102 pipeline highway crossings.

API 1102 is suitable for cased and uncased steel pipeline road and highway crossings.

Standard loads for single and tandem axle vehicles are included. The standard soil weight is 18.9 kN/m^3. Soil weight and wheel loads can also be user defined. The design factors are calculated from the figures. For input values outside the range in the figures the values are extrapolated (select either constant value or constant slope option). Extrapolated values should be used carefully.

Note : The calculations are based on the SI data values. User input values can be either US units or SI units. Change units on the setup page (click the Setup link on the calc bar). Units can be mixed, and do not need to be consistent.

Reference : API RP 1102 : Steel Pipelines Crossing Railroads and Highways (2012)

Change Module :

CALCULATOR MODULE : API RP 1102 Pipeline Railroad Crossing   ±

Calculate API RP 1102 pipeline railroad crossings.

API 1102 is suitable for cased and uncased steel pipeline railway crossings.

The design factors are calculated from the figures. Design factors are extrapolated for input values outside the range in the figures. Extrapolated values should be used carefully (select either constant value or constant slope option). The standard soil weight is 18.9 kN/m^3. Standard loads for single track and double track railroads are included. Soil weight and wheel loads can also be user defined.

Note : The calculations are based on the SI data values. User input values can be either US units or SI units. Change units on the setup page (click the Setup link on the calc bar). Units can be mixed, and do not need to be consistent.

Reference : API RP 1102 : Steel Pipelines Crossing Railroads and Highways (2012)

Change Module :

CALCULATOR MODULE : API RP 1102 Pipeline Crossing Design Factor   ±

Calculate API RP 1102 highway and railroad pipeline crossing design factors.

The design factors are calculated from the figures using the US values. Use the constant slope option to extrapolate values outside the range in the figures. Extrapolated values should be used carefully. Use the Result Plot option to display the selected figure with preset values (click the Result Plot button on the plot bar, then click the Make Plot button).

Reference : API RP 1102 : Steel Pipelines Crossing Railroads and Highways (2012)