Pipeng Toolbox : Pipe Snaking Modules Login
Short Cuts
GO
Main ±
Beams ±
References ±
Fluid Flow ±
Fluid Properties ±
Maths ±
Materials ±
Pipelines ±
Soils ±
Subsea ±
Data ±
Units ±
Help ±
Demo

Pipeline Snaking Or Lateral Buckling Modules

Links : ±
CALCULATOR MODULE : Beam Natural Vibration Frequency   ±

Calculate the damped and undamped beam natural vibration frequency for general beams (simply supported, fixed, and cantilever beams). For other beam types (eg circular beams) refer to the module links below.

The lateral natural vibration frequency beam end conditions are: pinned ends (simply supported beams), fixed ends, free fixed ends (cantilever beams), pinned fixed ends, and for beams with no load, pinned free ends, and free ends (unsupported beams). Added mass should be included for submerged or wet beams. The added mass coefficient can be calculated in accordance with DNVGL RP F105. The submerged natural frequency is calculated for still water conditions, with no vortex shedding. For beams on a soft foundation such as soil, use the effective length factor to allow for movement at the beam ends. For defined beam ends such as structures, the effective length factor should be set to one. The buckling load can be calculated using either the Euler equation (suitable for long beams), or the Johnson equation (suitable for short beams). The buckling load is dependent on the end type, and is used for mode 1 vibration only. Buckling normally occurs on the axis with lowest stiffness (I1 or I2). The bending stiffness for vibration and buckling can be defined separately for cases where vibration and buckling are not parallel.

`fn = ca.cd k / (2 π) √((EI) / (m . Le^4)) `
`ca =1 / (1 + F / (Fb))) `
`cd = √(1 - fd^2) `

where :

fn = lateral natural frequency [Hz]
ca = axial load coefficient
cd = damping coefficient
fd = damping factor (0 = undamped 1 = critical damping)
k = mode factor
L = effective beam length
EI = beam E I (bending modulus)
m = beam unit mass or mass per length
F = axial load (+ve in tension and -ve in compression)
Fb = buckling load

The longitudinal natural vibration frequency end conditions are: free fixed ends (cantilever), fixed ends, and free ends (unsupported). The fixed ends and free ends modes have the same natural frequencies, but different mode shapes. The longitudinal natural frequency is independent of cross section, and depends on the beam elastic modulus and density.

`fn = cd k / (2 π L) √(E / ρ) `

where :

fn = natural frequency [Hz]
cd = damping coefficient
k = mode factor
L = beam length
E = beam elastic modulus
ρ = beam density

The torsional natural vibration frequency end conditions are: free fixed ends (cantilever), fixed ends, and free ends (unsupported). The fixed ends and free ends modes have the same natural frequencies, but different mode shapes. The torsional natural frequency is independent of cross section, and depends on the beam shear modulus and density.

`fn = cd k / (2 π L) √(G / ρ) `

where :

fn = natural frequency [Hz]
cd = damping coefficient
k = mode factor
L = beam length
G = beam shear modulus
ρ = beam density

The mode factor k is dependent on the mode number, and the beam end type. The k factors have been taken from the Shock and Vibration handbook. The damping factor should be set to zero for undamped vibration or set greater than zero and less than or equal to one for damped vibration.

Use the Result Table and Result Plot options to display tables and plots. Refer to the figures and help pages for more details about the tools. Refer to the links below for other beam options.

References :

Shock And Vibration Handbook, Cyril M Harris, McGraw Hill
Roark's Formulas For Stress And Strain, Warren C Young, McGraw Hill

Change Module :

CALCULATOR MODULE : Beam Lateral Vibration Frequency   ±

Calculate the damped and undamped beam natural vibration frequency for lateral vibration (simply supported, fixed, and cantilever beams).

Added mass should be included for submerged or wet beams. The added mass coefficient can be calculated in accordance with DNVGL RP F105. The submerged natural frequency is calculated for still water conditions, with no vortex shedding. For beams on a soft foundation such as soil, use the effective length factor to allow for movement at the beam ends. For defined beam ends such as structures, the effective length factor should be set to one.

The mode factor k is dependent on the mode number, and the beam end type. The k factors have been taken from the Shock and Vibration handbook. The damping factor should be set to zero for undamped vibration or set greater than zero and less than or equal to one for damped vibration. For multi layer pipes the bending stiffness can be calculated with the concrete stiffness factor (CSF). The CSF accounts for the additional stiffness provided by the external concrete coating. The concrete stiffness factor is calculated in accordance with DNVGL RP F105. Enter the wall thickness for all layers. Only enter the elastic modulus for layers which affect the pipe stiffness.

Use the Result Table and Result Plot options to display tables and plots. Refer to the figures and help pages for more details about the tools.

References :

Shock And Vibration Handbook, Cyril M Harris, McGraw Hill
Roark's Formulas For Stress And Strain, Warren C Young, McGraw Hill

Change Module :

CALCULATOR MODULE : Beam Lateral Vibration Frequency With Axial Load   ±

Calculate the damped and undamped beam natural vibration frequency for lateral vibration with axial load (simply supported, fixed, and cantilever beams).

For beams with axial load the axis with minimum stiffness (I1 or I2) should be used unless the beam is constrained to deflect on an alternative axis (buckling normally occurs on the minimum stiffness axis). Use the general beam calculators for cases where vibration and buckling are not parallel. The buckling load can be calculated using either the Euler equation (suitable for long beams), or the Johnson equation (suitable for short beams). The buckling load is dependent on the end type, and is used for mode 1 vibration only.

Added mass should be included for submerged or wet beams. The added mass coefficient can be calculated in accordance with DNVGL RP F105. The submerged natural frequency is calculated for still water conditions, with no vortex shedding. For beams on a soft foundation such as soil, use the effective length factor to allow for movement at the beam ends. For defined beam ends such as structures, the effective length factor should be set to one. For pipes the axial load is calculated from temperature and pressure. For general beams the axial load is user defined.

The mode factor k is dependent on the mode number, and the beam end type. The k factors have been taken from the Shock and Vibration handbook. The damping factor should be set to zero for undamped vibration or set greater than zero and less than or equal to one for damped vibration. For multi layer pipes the bending stiffness can be calculated with the concrete stiffness factor (CSF). The CSF accounts for the additional stiffness provided by the external concrete coating. The concrete stiffness factor is calculated in accordance with DNVGL RP F105. Enter the wall thickness for all layers. Only enter the elastic modulus for layers which affect the pipe stiffness.

Use the Result Table and Result Plot options to display tables and plots. Refer to the figures and help pages for more details about the tools.

References :

Shock And Vibration Handbook, Cyril M Harris, McGraw Hill
Roark's Formulas For Stress And Strain, Warren C Young, McGraw Hill

Change Module :

CALCULATOR MODULE : Hot Pipeline Hobbs Lateral And Upheaval Buckling   ±
CALCULATOR MODULE : Hot Pipeline Lateral Buckling   ±
CALCULATOR MODULE : Hot Pipeline Upheaval Buckling Trigger   ±

Calculate high temperature pipeline upheaval buckling trigger height using Hobbs method.

Upheaval buckling triggers are used to initiate controlled buckling of high temperature high pressure pipelines. The trigger height should be designed so that the upheaval buckling initiation temperature is lower than the lateral buckling initiation temperature for all four lateral buckling modes. The triggers should be spaced according to the buckle initiation slip length. Use the Result Plot option to display the buckle initiation temperature versus either lateral out of straightness or trigger height, and use the goal seek option to calculate the required trigger height.

Change Module :

CALCULATOR MODULE : DNVGL RP F109 Submarine Pipeline Stability   ±

Calculate DNVGL-RP-F109 pipeline lateral and vertical stability.

Static or absolute stability can be calculated for clay seabed, sandy seabed (D50 ≤ 50 mm), or rocky seabed (D50 > 50 mm). The single oscillation velocity corresponds to the maximum wave velocity in the return period. Maximum current velocity data should be used.

Dynamic stability can be calculated on clay and sandy seabeds for Lstable (pipe displacement ≤ 0.5 OOD), L10 (pipe displacement ≤ 0.5 OOD), or user defined pipe displacement. Significant current velocity data should be used.

Seabed wave velocity is calculated from the JONSWAP surface spectrum with an Airy wave transfer function. The calculation should only be used for elevations at or near the seabed. The Airy wave transform may not be valid in shallow water.

Reference : DNVGL-RP-F109 : On-Bottom Stability Design Of Submarine Pipelines (Download from the DNVGL website)

Change Module :

CALCULATOR MODULE : DNVGL RP F109 Check Value   ±