Pipeng Toolbox : ASME B31.8 Temperature Factor Calculators Blank User
Short Cuts
GO
Main ±
Beams ±
References ±
Fluid Flow ±
Fluid Properties ±
Maths ±
Materials ±
Pipelines ±
Soils ±
Subsea ±
Demo

ASME B31.8 Gas Pipeline Temperature Derating

Calculate ASME B31.8 gas pipeline temperature derating for onshore and offshore steel pipelines (carbon steel and low alloy steel?). The temperature derating factor is not valid for nickel alloy or stainless steel pipelines.

Reference : ANSI/ASME B31.8 : Gas Transmission And Distribution Piping Systems (2018)

Change Module :

[FREE] tools are free in basic mode with no login (no plots, tables, goal seek etc). Login or Open a free account to use the tools in plus mode (with plots, tables, goal seek etc).
[PLUS] tools are free in basic CHECK mode with Login or Open a free account (CHECK values no plots, tables, goal seek etc). Buy a Subscription to use the tools in plus mode (with plots, tables, goal seek etc).
Try plus mode using the Plus Mode Demo tools with no login.   Help Using The Pipeng Toolbox (opens in the popup workbook)

Links : ±
CALCULATOR : ASME B31.8 Section 841.1 Pipeline Temperature Derated Yield Stress And Tensile Stress [FREE]   ±

Calculate temperature derating factor, and derated yield stress and tensile stress from temperature (ASME B31.8 section 841.1).

Refer to Table 841.1.8-1 for the derating factors. The derating factors are valid for steel pipe upto 232 C (450 F). For temperatures above 232 C (450 F) the derating values should be used carefully (material specific test data should be used if it is available). The derating factor is assumed to be valid for yield stress and tensile stress. Use the Result Table option to display the results for the selected stress table (API, ASME or DNV). The temperature derating factor is not valid for nickel alloy, or stainless steel.

Tool Input

  • syutype : Stress Table Type
  • mattype : Material Type
    • SMYSu : User Defined Specified Minimum Yield Stress
    • SMTSu : User Defined Specified Minimum Tensile Stress
  • tfactype : Temperature Derating Factor Type
    • Td : Design Temperature
    • Tu : User Defined Temperature Derating Factor

Tool Output

  • SMTS : Specified Minimum Tensile Stress
  • SMTS/SMYS : Tensile Stress Over Yield Stress Ratio
  • SMYS : Specified Minimum Yield Stress
  • SMYS/SMTS : Yield Stress Over Tensile Stress Ratio
  • Su : Derated Tensile Stress
  • Sy : Derated Yield Stress
  • T : Temperature Derating Factor

CALCULATOR : ASME B31.8 Section 841.1 Pipeline Temperature Derating Factor [FREE]   ±

Calculate temperature derating factor from temperature (ASME B31.8 section 841.1).

Refer to Table 841.1.8-1 for the derating factors. The derating factors are valid for steel pipe upto 232 C (450 F). For temperatures above 232 C (450 F) the derating values should be used carefully (material specific test data should be used if it is available). The temperature derating factor is not valid for nickel alloy, or stainless steel. Use the Result Plot option to plot the derating factor.

Tool Input

  • Td : Design Temperature

Tool Output

  • T : Temperature Derating Factor