Calculate ASME B31.5 refrigeration piping maximum allowable design pressure from wall thickness and design temperature .
Allowable stress is calculated from temperature using Table 502.3.1 (US values). Change units on the setup page. Stress values can be extrapolated for temperatures above the data range (care is required when using extrapolated values). For combined internal and external pressure the allowable pressure is equal to the maximum allowable pressure difference.
Use the data plot option to plot the allowable stress versus temperature for the selected material. Use the Data Table option to display the relevant data table. Use the Result Table option to display a table of allowable pressure versus wall thickness for the selected pipe schedule.
Reference : ANSI/ASME B31.5 : Refrigeration Piping And Heat Transfer Components (2013)
Links : ± |
CALCULATOR : ASME B31.5 Section 504.1 Pipe Schedule Diameter And Wall Thickness [FREE] ±
Calculate ASME B31.5 pipe diameter, minimum wall thickness and pressure design thickness from pipe schedule or user defined diameter and wall thickness (ASME B31.5 section 504.1). Select the pipe schedule (NPS or ISO), pipe diameter and wall thickness, or use the user defined option. Use the Result Table option to display the pipe schedule with nominal wall thickness, minimum wall thickness and pressure design wall thickness for the selected diameter. Tool Input- schdtype : Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- txu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- c : Wall Thickness Corrosion Allowance
Tool Output- ID : Nominal Inside Diameter
- OD : Nominal Outside Diameter
- OD/tn : Diameter Over Wall Thickness Ratio
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- tp : Pressure Design Wall Thickness
- tx : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Pipe Design Pressure (General) [FREE] ±
Calculate ASME B31.5 general pipe design pressure from diameter, wall thickness, wall thickness tolerance and design stress). The hoop stress is equal to the design stress at the design pressure. External pressure should be ignored (use the no external pressure option). For ASME B31.5 pipe use the Barlows equation with ASME Y factor option. Wall thickness tolerance can be defined by either a fraction tolerance, or an allowance tolerance. All tolerances should be positive. The corrosion allowance should include mechanical allowance (eg threads), erosion allowance and any other allowances. Tool Input- pletype : External Pressure Type
- Peu : User Defined External Pressure
- schdtype : Pipe Schedule Type
- diamtype : Pipe Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- syutype : Stress Table Type
- mattype : Yield Stress Type
- SMYSu : User Defined Specified Minimum Yield Stress
- sdtype : Design Stress Type (F x SMYS)
- Fu : User Defined Design Factor
- Sdu : User Defined Design Stress
- walltype : Hoop Stress Calculation Type
- Yu : User Defined ASME Y Factor
- tc : Corrosion Allowance
Tool Output- ID : Pipe Inside Diameter
- OD : Pipe Outside Diameter
- OD/tn : Pipe Diameter Over Wall Thickness Ratio
- Pd : Design Internal Pressure
- PdΔ : Design Delta Pressure
- Pe : External Pressure
- SMYS : Specified Minimum Yield Stress
- Sd : Design Stress
- tf : Fabrication Allowance
- tfx : Fabrication Fraction
- th : Hoop Stress Thickness (Pressure Containment)
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
|
CALCULATOR : ASME B31.5 Section 504.1 Pipe Design Pressure From Wall Thickness [FREE] ±
Calculate pipe maximum allowable design pressure from wall thickness (ASME B31.5 section 504.1). Allowable stress values should be taken from table 302.3.1 (or use the allowable stress calculators). All user defined tolerances should be positive. The corrosion allowance should include mechanical allowance (eg threads), erosion allowance and any other allowances. Tool Input- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- S : Maximum Allowable Stress Table 502.3.1
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Nominal Wall Thickness Ratio
- PR : Rated Pressure
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Carbon Steel Seamless Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for carbon steel seamless pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Carbon Steel Welded Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for carbon steel welded pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Carbon Steel Electric Resistance Welded Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for carbon steel electric resistance welded pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Carbon Steel Electric Fusion Welded Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for carbon steel electric fusion welded pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Carbon Steel Copper Brazed Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for carbon steel copper brazed pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Alloy Steel Seamless Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for alloy steel seamless pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Alloy Steel Electric Resistance Welded Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for alloy steel electric resistance welded pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Austenitic Stainless Steel Seamless Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for austenitic stainless steel seamless pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Austenitic Stainless Steel Welded Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for austenitic stainless steel welded pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Copper Alloy Seamless Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for copper alloy seamless pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Copper Alloy Welded Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for copper alloy welded pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Nickel Alloy Seamless Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for nickel alloy seamless pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Aluminium Alloy Seamless Pipe And Tube [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for aluminium alloy seamless pipe and tube (ASME B31.5 section 504.1 and Table 502.3.1 US units). Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Iron Castings [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for iron castings (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|
CALCULATOR : ASME B31.5 Table 502.3.1 Pipe Design Pressure From Temperature Carbon Steel Plate And Sheet [PLUS] ±
Calculate allowable stress and pipe maximum allowable design pressure from temperature for carbon steel plate and sheet (ASME B31.5 section 504.1 and Table 502.3.1 US units). The minimum temperature is specified as either a numeric value (eg -20), or as curve A, B or C from Table 523.2.2. The minimum temperature is also dependent on the stress ratio. Use the minimum temperature calculators to calculate the minimum temperature. Tool Input- datatype : Material Type And Grade
- OOR : If Temperature Above Data Range
- schdtype : Pipe Schedule Type
- diamtype : Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Fabrication Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- yfactype : Y Factor Type
- Yu : User Defined Y Coefficient
- c : Corrosion Allowance
- T : Design Temperature
Tool Output- D : Pipe Outside Diameter
- D/t : Pipe Diameter Over Pressure Design Thickness Ratio
- D/tn : Pipe Diameter Over Wall Thickness Ratio
- PR : Rated Pressure
- S : Maximum Allowable Stress Table 502.3.1
- S [Pa] : Maximum Allowable Stress
- Sdata : Stress Data
- T [C] : Design Temperature
- Tdata : Temperature Data
- Tmin : Minimum Temperature
- Y : Y Factor
- d : Pipe Inside Diameter
- t : Pressure Containment Wall Thickness
- tf : Wall Thickness Fabrication Allowance
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness
- xf : Wall Thickness Fabrication Fraction
|