PRCI PR 3805 RSTRENG
Calculate PR-3-805 RSTRENG piping level 0 corrosion defect assessment for blunt defects (corrosion defects or other defects). The level 0 assessment is useful as a screening check. The allowable defect length is calculated from the maximum defect depth. The calculation is taken from ASME B31G 1999 (original ASME B31G). The level 0 check is suitable for blunt defects of all types, including corrosion, mechanical damage and grinding repairs etc. For crack type defects the NG-18 crack defect calculators are recommended. The RSTRENG method (effective area method) can also be used for blunt type defects. The temperature derating calculation is from ASME B31.8. Material specific test data should be used if it is available. Defects failing the level 0 check should be checked with a level 1 or level 2 assessment (see module links below). Use the level 1 assessment for simple defects from defect length and depth using the 0.85 RSTRENG equation. Use the level 2 assessment for complex defects from the defect river bottom profile using the RSTRENG method or effective area method. Reference : PRCI, Pipeline Research Committee Project, PR-3-805, “A Modified Criterion for Evaluating the Remaining Strength of Corroded Pipe,” December 22, 1989, PRCI PR-3-805 (R-STRENG) With RSTRENG Disk. Change Module :
[FREE] tools are free in basic mode with no login (no plots, tables, goal seek etc). Login or Open a free account to use the tools in plus mode (with plots, tables, goal seek etc).
[PLUS] tools are free in basic CHECK mode with Login or Open a free account (CHECK values no plots, tables, goal seek etc). Buy a Subscription to use the tools in plus mode (with plots, tables, goal seek etc).
Try plus mode using the Plus Mode Demo tools with no login. Help Using The Pipeng Toolbox (opens in the popup workbook)
Links : ± |
CALCULATOR : PR-3-805 RSTRENG Level 0 Corrosion Defect Screening Assessment [FREE] ±
Calculate defect screening assessment and allowable defect length from the maximum defect depth for PR-3805 RSTRENG. The allowable defect length is based on the original ASME B31G (1999). Defects which fail the screening assessment require further assessment, or repair. Reference : ANSI/ASME B31G Manual For Determining The Remaining Strength Of Corroded Pipelines Tool Input- schdtype : Line Pipe Schedule Type
- diamtype : Pipe Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- L : Defect Length
- d : Defect Maximum Depth
Tool Output- B : Defect B Value
- Ba : Defect Allowable B Value
- ID : Pipe Inside Diameter
- La : Defect Allowable Length
- OD : Pipe Outside Diameter
- d/t : Defect Depth Over Wall Thickness Ratio
- t : Pipe Wall Thickness
- tmin : Defect Minimum Remaining Wall Thickness
|
CALCULATOR : PR-3-805 RSTRENG Pipe Diameter From Circumference [FREE] ±
Calculate pipe outside diameter from circumference, or pipe circumference from outside diameter for RSTRENG. Use either the nominal pipe diameter and wall thickness, or the measured pipe diameter and wall thickness for the RSTRENG checks. Tool Input- odtype : Pipe Outside Diameter Measurement Type
- ODu : Measured Outside Diameter
- OCu : Measured Outside Circumference
Tool Output- OC : Pipe Outside Circumference
- OD : Pipe Outside Diameter
|
|
---|