Calculate API RP 1111 general pipeline hoop stress or wall stress from diameter, wall thickness and design stress.
Pipe wall stress can be calculated for either the nominal wall thickness, the minimum wall thickness (nominal wall thickness minus fabrication allowance), or the hoop stress wall thickness (nominal wall thickness minus fabrication allowance and corrosion allowance).
For API RP 1111 pipe, select either the Barlow's equation midwall diameter option, or the log equation option. The manufacturing tolerance is ignored (set the manufacturing tolerance to zero). The corrosion allowance should include mechanical allowance (eg threads), erosion allowance and any other allowances.
Tool Input
- pletype : External Pressure Type
- Peu : User Defined External Pressure
- schdtype : Pipe Schedule Type
- diamtype : Pipe Diameter Type
- ODu : User Defined Outside Diameter
- IDu : User Defined Inside Diameter
- wtntype : Wall Thickness Type
- tnu : User Defined Wall Thickness
- ttoltype : Wall Thickness Tolerance Type
- xfu : User Defined Negative Wall Thickness Fraction
- tfu : User Defined Negative Wall Thickness Allowance
- syutype : Stress Table Type
- mattype : Yield Stress Type
- SMYSu : User Defined Specified Minimum Yield Stress
- sdtype : Design Stress Type (F x SMYS)
- Fu : User Defined Design Factor
- Sdu : User Defined Design Stress
- walltype : Hoop Stress Calculation Type
- Yu : User Defined ASME Y Factor
- hooptype : Hoop Stress Wall Thickness Type
- tc : Corrosion Allowance
- Pi : Internal Pressure
Tool Output
- ID : Pipe Inside Diameter
- OD : Pipe Outside Diameter
- OD/tn : Pipe Diameter Over Wall Thickness Ratio
- PΔ : Pressure Difference
- Pe : External Pressure
- SMYS : Specified Minimum Yield Stress
- Sd : Design Stress
- Sh : Hoop Stress
- Sh/Sd : Hoop Stress Over Design Stress Ratio
- tf : Fabrication Allowance
- tfx : Fabrication Fraction
- th : Hoop Stress Thickness (Pressure Containment)
- tm : Minimum Wall Thickness
- tn : Nominal Wall Thickness