Pipeng Toolbox : Steam Flowrate Calculators Blank User
Short Cuts
GO
Main ±
Beams ±
References ±
Fluid Flow ±
Fluid Properties ±
Maths ±
Materials ±
Pipelines ±
Soils ±
Subsea ±
Demo

IAPWS R7-97 Steam Volume And Mass Flow Rate

Calculate IAPWS R7-97 steam table properties, and steam power from temperature, pressure and mass flow rate.

Steam table properties can be calculated for water and steam, saturated water, saturated steam, saturated water and steam, metastable water, and metastable steam. The enthalpy rate and internal energy rate (or power) are calculated from the mass flow rate.

Note : There is an anomaly in the steam calculation for region 3 between the saturated vapour line, the region 2/3 boundary, and the critical pressure. Refer to the region 3 anomaly help page for more details (click the utility button on the data bar). IAPWS R7-97 is intended for industrial use, and is a simplified version of IAPWS R6-95 for scientific use. IAPWS R7-97 was developed as an improvement of the IFC-67 model.

Reference : IAPWS R7-97 Industrial Formulation for thermodynamic Properties of Water and Steam

Change Module :

[FREE] tools are free in basic mode with no login (no plots, tables, goal seek etc). Login or Open a free account to use the tools in plus mode (with plots, tables, goal seek etc).
[PLUS] tools are free in basic CHECK mode with Login or Open a free account (CHECK values no plots, tables, goal seek etc). Buy a Subscription to use the tools in plus mode (with plots, tables, goal seek etc).
Try plus mode using the Plus Mode Demo tools with no login.   Help Using The Pipeng Toolbox (opens in the popup workbook)

Links : ±
CALCULATOR : IAPWS R7-97 Steam Table [FREE]   ±

Calculate steam table from temperature and pressure (IAPWS R7-97 Steam Table).

Steam table values can be calculated for water and steam, saturated water, saturated steam, saturated water and steam, metastable water, and metastable steam. The calculations for water and steam are valid between 273.15 K and 1073.15 K (0 to 100 MPa), and between 1073.15 K and 2273.15 K (0 to 50 MPa).

The saturated water and steam calculations are valid between 273.15 K and 647.096 K.

The metastable calculation is valid between 273.15 K and 647.096 K, and for pressure from the saturated vapour line to the 5% equilibium moisture line (user defined). Use the Result Plot option to plot the steam properties versus temperature and pressure.

Tool Input

  • anomtype : Region 2/3 Anomaly Type
  • proptype : Steam Phase
    • Pu : User Defined Pressure
    • Tu : User Defined Temperature
    • Xu : User Defined Saturated Steam Quality

Tool Output

  • ρ : Density
  • Cp : Specific Heat Constant Pressure
  • Cp-Cv : Delta Specific Heat (Cp - Cv)
  • Cp/Cv : Specific Heat Ratio
  • Cv : Specific Heat Constant Volume
  • P : Pressure
  • T : Temperature
  • Vc : Speed Of Sound
  • Z : Compressibility Factor
  • cvg : Convergence Check
  • h : Enthalpy
  • s : Entropy
  • u : Internal Energy
  • vg : Mole Specific Volume
  • vm : Specific Volume
  • wv : Specific Weight

CALCULATOR : IAPWS R7-97 Steam Piping Mass And Volume Flow Rate [PLUS]   ±

Calculate water and steam properties and power from temperature, pressure and mass flow rate (IAPWS R7-97 Steam Table).

Properties can be calculated for water and steam, saturated water, saturated steam, saturated water and steam, metastable water, and metastable steam. The calculations for water and steam are valid between 273.15 K and 1073.15 K (0 to 100 MPa), and between 1073.15 K and 2273.15 K (0 to 50 MPa).

The saturated water and steam calculations are valid between 273.15 K and 647.096 K.

The metastable calculation is valid between 273.15 K and 647.096 K, and for pressure from the saturated vapour line to the 5% equilibium moisture line (user defined). Use the Result Plot option to plot the steam properties versus temperature and pressure.

Tool Input

  • schdtype : Pipe Schedule Type
  • diamtype : Pipe Diameter Type
    • ODu : User Defined Outside Diameter
    • IDu : User Defined Inside Diameter
  • wtntype : Wall Thickness Type
    • tnu : User Defined Wall Thickness
  • anomtype : Region 2/3 Anomaly Type
  • proptype : Steam Phase
    • Pu : User Defined Pressure
    • Tu : User Defined Temperature
    • Xu : User Defined Saturated Steam Quality
  • voltype : Steam Flow Rate Type
    • Mu : User Defined Steam Mass Flow Rate
    • Qu : User Defined Steam Volume Flow Rate
    • Vu : User Defined Steam Velocity

Tool Output

  • ρ : Density
  • AX : Pipe Internal Area
  • Cp : Specific Heat Constant Pressure
  • Cp-Cv : Delta Specific Heat (Cp - Cv)
  • Cp/Cv : Specific Heat Ratio
  • Cv : Specific Heat Constant Volume
  • H : Enthalpy Rate
  • Ho : Stagnation Enthalpy Rate
  • ID : Inside Diameter
  • M : Steam Mass Flow Rate
  • P : Pressure
  • Q : Steam Volume Flow Rate
  • T : Temperature
  • U : Internal Energy Rate
  • V : Steam Velocity
  • Vc : Speed Of Sound
  • Z : Compressibility Factor
  • cvg : Convergence Check
  • h : Enthalpy
  • ho : Stagnation Enthalpy (h + 0.5 V^2)
  • s : Entropy
  • u : Internal Energy
  • vg : Mole Specific Volume
  • vm : Specific Volume
  • wv : Specific Weight

CALCULATOR : IAPWS R7-97 Steam Pipe Inside Diameter And Cross Section Area [FREE]   ±

Calculate IAPWS R7-97 steam pipe inside diameter and cross section area from pipe diameter and wall thickness.

Select the pipe schedule type, diameter and wall thickness, or use the user defined option. Use the Result Table option to display a table of the inside diameter and cross section area versus either outside diameter or wall thickness.

Tool Input

  • schdtype : Schedule Type
  • diamtype : Diameter Type
    • ODu : User Defined Outside Diameter
    • IDu : User Defined Inside Diameter
  • wtntype : Wall Thickness Type
    • tnu : User Defined Wall Thickness

Tool Output

  • AX : Pipe Inside Cross Section Area
  • ID : Nominal Inside Diameter
  • OD : Nominal Outside Diameter
  • OD/tn : Diameter Over Wall Thickness Ratio
  • tn : Nominal Wall Thickness