| CALC : Pipe : Wall Thickness 034 : Pipeline And Tubular Dent Displacement And Energy From Dent Force : Calculator
Description : Calculate the dent absorbed energy and dent depth from the dent force for a pipeline or circular tubular structure.
Discussion : Use this calculator to assess pipeline dents for known indentation force.
Calculation Steps :
Options :
- Dent model : Ellinas Walker : General : Wierzbicki Suh
Input Variables :
- D = Pipe Nominal Diameter
- F = Pipeline Applied Dent Force
- Sy = Pipeline SMYS - Specified Minimum Yield Stress
- Z = Dent Type
- tn = Pipe Nominal Wall Thickness
Output Variables :
- E = Pipeline Dent Absorbed Energy
- d = Pipeline Dent Depth
Calculation :
If Z = 1 : Ellinas Walker
d = ( F / ( 37.5 Sy tn 2 ) ) 2 D
E = 25 Sy tn 2 d 3 / 2 / √( D )
Otherwise If Z = 2 : General
d = ( F / ( 5.3033 Sy tn 2 ) ) 2 tn
E = 3.6 Sy tn 2 d 3 / 2 / √( tn )
Otherwise If Z = 3 : Wierzbicki Suh
d = ( F / ( 5.78881 Sy tn 2 ) ) 2 tn
E = 3.85921 Sy tn 2 d 3 / 2 / √( tn )
End of If Block
Back To Top
|