| CALC : Pipe : Wall Thickness 044 : ASME B31.3 Pipeline Operating Pressure From Leak Test Pressure - High Temperature : Calculator
Description : Calculate the pipeline allowable operating pressure from the pipeline internal leak test pressure - high temperature method.
Discussion : Allowable operating pressure for high temperature pipelines where the allowable stress at the design temperature is lower thasn the allowable stress at the leak test temperature.
References :
Input Variables :
- Pt = Pipeline Leak Test Gauge Pressure
- S = Allowable Hoop Stress
- St = Allowable Test Hoop Stress
Output Variables :
- P = Pipeline Design Gauge Pressure
Calculation :
P = ( Pt S ) / ( 1.5 St )